Dehumidification
If the room temperature falls to more than 2 °C below the value set, the fan in the indoor and outdoor
compartments stops. At room temperatures of ± 2 °C above or below the temperature set, the device
switches to dehumidification mode. If room temperature rises to more than 2 °C above the temperature set,
the device switches to cooling mode.
A temperature between 16 °C and 30 °C can be selected. In dehumidification mode the device operates on
AUTOFAN.
1. Press the 1 / 0 key.
2. Select “Dehumidification” with the MODE key.
3. Set the airflow fins (they determine the outflow direction of the air) by pressing the SWING key.
4. Set the desired temperatures using the +/- (or +°C / -°C) keys.