Dimplex Heatbook
Technical information
Colour/Finish
All units supplied with a choice of white,
dark brown and stainless steel fascias.
Stainless steel fascia
Brown fascia
White fascia
Note: Above grille close ups are for colour
reference only. For actual grille please refer
to main photography.
Elements – all models
Fully strung, helically wound,
800W and 1600W combine to
give 2400W maximum output.
Thermostat – all models
Bi-metal type, air temperature sensing.
Electrical connections
• Remote control model:
2.5 metre 6 core colour coded cable
is supplied for connecting the heater
to the switch panel. The installer must
supply suitable conduit or trunking
if required and a surface or flush
mounting box for the switch panel.
A list of suitable standard boxes
is supplied with the heater.
• Integral control model:
Supplied with 2m, 3-core cable.
Thermal safety device
Interrupt supply to reset type.
BASE UNIT HEATERS
20 min
up to
75
100
min
over 75
Installation/dimensions (mm)
Aperture
120
min
460
12 min
12 min
96 Plinth
Aperture dimensions
360
Cable
entry
Ensure
air inlet
grille is
clear
Plan
All models
210
22
90
Rear support bracket
Side view
500
260
80
120
Front view
If the overhang above
the heater is greater than
75mm, then a distance
of at least 100mm must
be maintained between
the overhang and the
uppermost part of the heater.
Note:
If fitted in corner with adjacent cupboards to right hand side of heater then a distance of at least 150mm must
be maintained between the right hand end of the heater and the front of the adjacent cupboard door as shown.
145
86
Installation
Minimum back box depth of 40mm
is required behind fascia plate.
Switch panel remote control models
57
The BFH range
Commentaires sur ces manuels