Controls
Charge controller
Type: Hydraulic, manually
adjustable from zero charge
to fully charged condition.
Thermal safety device
Type: Bi-metal – automatic reset.
Output control
Type: Integral room temperature
sensing hydraulic thermostat fitted at
installation stage. Accurate to ±1°C.
Temperature range approximately
5°C to 30°C.
On/off switch for fan.
On/off switch with neon for direct
acting heating element (option).
These qualities make this range
of heaters the perfect solution for
commercial applications where a reliable,
energy efficient system is needed.
The range has the dual benefits of
The VFMi range of fan storage heaters blends all the benefits of using low tariff electricity
with a highly insulated heater to give maximum controllability over heat delivered.
dependable thermostatic control and
a quiet fan heat distribution for fast
response. In addition, it is possible to
link the fan circuit to a separate timer for
even greater levels of controllability.
The VFMi range
HIGH OUTPUT
FAN STORAGE HEATERS
Model VFM24i VFM32i VFM40i VFM48i
Performance
Input rating 3.4kW 4.6kW 5.7kW 6.9kW
Charge acceptance 7 hour 24kWh 32kWh 40kWh 48kWh
Heating elements/fans
No. of elements/rating
(off-peak supply)
3 x 1130W 3 x 1530W 3 x 1900W 3 x 2300W
Fan rating (on-peak supply) 15W 15W 25W 25W
Dimensions
Height 672mm 672mm 672mm 672mm
Width 776mm 926mm 1076mm 1226mm
Depth (inc. 35mm wall spacer) 285mm 285mm 285mm 285mm
Weight (installed) 138kg 177kg 216kg 255kg
No. of storage bricks 18 24 30 36
Brick packs 6 8 10 12
Optional direct acting element
zHi 070E input rating 0.7kW 3 3 3 3
zHi 110E input rating 1.1kW N/A 3 3 3
zHi 150E input rating 1.5kW N/A N/A 3 3
zHi 200E input rating 2.0kW N/A N/A 3 3
3 = installation possible
Features
Loadings from 3.4 to 6.9kW
Highly accurate thermostat for
close control over retained heat
Controls conveniently positioned
on the top right-hand side of
the heater
Manually adjustable input
charge control
Frost protection setting
Optional direct acting
elements available
Accessory feet available for use
on uneven surfaces or thick carpets
(only applicable when heater is
fixed to wall)
Ideal for ofces, hotels, community
rooms, halls and larger homes
86